Performance

Altaros Compressor unit works on inlet pressure amplifiers principle. For these reasons it is necessary for its function source of pressurized air. As a source of compressed air may be used ordinary workshop compressor that provides at least 5 bar / 72 PSI  and a maximum of 10bar / 145 PSI . Bottle filling speed depends on high pressure air and its amount supplied from the driving workshop compressor. For a better idea about the high pressure air filling speed we have prepared a table with real measurement for different types of workshop compressors, that differ in amount of supplied air quantity and volume of the outlet pressure and compressor load in %. This “Load” figure represents the ratio of time in%, when driving the compressor is in operation (For example 65% indicates that the compressor drive 65% of the time is in operation and 35% of its motor is stopped and pressurized air is consumed to drive only from the compressor air chamber). In the table are shown times for filling bottles of different sizes and pressures and also the amount of supplied air, in liters per minute, which is a value that can be used to calculate the time required for filling bottles of any size and the desired pressure difference. For illustration, here is an example:

Bottle which we want to fill has a capacity of 7 liters and the requirement to fulfill it from the pressure of 100bar to 300bar pressure.First, we calculate the total quantity of air required to fill the bottle by multiplying its air volume sizes of the differential pressures, namely 7 x L (300-100 bar) = 1400L air at a pressure of 1 bar (atmospheric pressure). This result is then divided by the data in the table. When using these data:

Compressor Drive: Load 65%  Supplied quantity from the booster compressor: 11.4 L / min / 0.40 cfm

We can calculate final time that required volume is divided by “Supplied quantity“, therefore

1400L /11,4 L/min = 122 minutes. Thus Filling 7 litres cylinders (from 100 to 300 bar) to desired pressure, it should take about two hours when using this drive compressor.

When we use different driving compressor with different Supplied quantity 8,8L/min then our filling time would be 1400L / 8,8L/min = 160min

This way you can calculate the approximate filling time for different air volumes, pressure differences and different driving compressors.

___________________________________________________________________

 

Driving compressor: Schneider Bohemia: UNM 410-10-50 W

schneider UNM 410

Input power 2,2kW / 3HP
2 cylinders
Max pressure. 10 bar   / 145 PSI
Air intake 410 l/min     /   15.5 cfm
Filling amount 295 l/min   /  10.4 cfm
Realistically measured amount of airflow 350 l/min   /   12.3 cfm

Driving compressor Supplied quantity Filling time for different airvolume and different pressure
4l/42 cf   200-300bar

(2900-4500 PSI)

0,8l/8,5cf  100-200bar

( 1500-2900 PSI)

0,3l/3,2cf   1000-3000PSI

 

Load 100% 16l/min

0.55 cfm

25min 6.5min 3,75min
Load 65% 11,4l/min

0.40 cfm

35min 8,5min 4,5min

___________________________________________________________________

Hecht 2351

Driving compressor: Hecht 2351
Input power 2,2kW / 3HP
2 cylinders
Max pressure 8 bar  /  116 PSI
Air intake 400 l/min   /  14.1 cfm
Realistically measured amount of airflow 250 l/min  /   8.8 cfm

Driving compressor Supplied quantity Filling time for different airvolume and different pressure
4l/42 cf 200-300bar

(2900-4500 PSI)

0,8l/8,5cf 100-200bar

( 1500-2900 PSI)

0,3l/3,2cf 1000-3000PSI
Load 100% 8,8l/min

0.31 cfm

45min 11min 5,7min
Load 65% 5,3l/min

0.19 cfm

75min 15min 8 min

 

___________________________________________________________________

scheppach HC 24

 

 

Driving compressor:   Scheppach HC 24
Input power 1,5 kW / 2 HP
1 cylinder
Max pressure 8 bar   /  116 PSI
Air intake 220 l/min   /   7.8 cfm
Realistically measured amount of airflow 125l/min   /  4.4 cfm

 

 

Driving compressor Supplied quantity Filling time for different airvolume and different pressure
4l/42 cf  200-300bar

(2900-4500 PSI)

0,8l/8,5cf  100-200bar

( 1500-2900 PSI)

0,3l/3,2cf 1000-3000PSI
Load 100% 4,5l/min

0.16 cfm

90min 19min 9,5min
Load 65% 2,7l/min

0.095 cfm

150min 30min 15,5min

Comments are closed.